  • ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll ma ọ bụ protocol na-abụghị ọkọlọtọ na Ntụgharị ProfiNet

    ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll ma ọ bụ protocol na-abụghị ọkọlọtọ na Ntụgharị ProfiNet

    ODOT-PNM02 V2.1

    Modbus (nna ukwu / ohu, RTU / ASCII) na ProfiNET, ọdụ ụgbọ mmiri 2 (RS485/ RS232 / RS422), na-akwado oghere 50, iwu 200 na TIA

    Portal (site na ngwanrọ ahaziri), na-akwado ndị ohu MAX 60

    ♦ Na-akwado ntụgharị protocol n'etiti Modbus na PROFINET

    ♦ Na-akwado 2* RS485/RS232 ma ọ bụ 1*RS422

    ♦ Na-akwado Modbus master ma ọ bụ ohu, ma na-akwado RTU ma ọ bụ ASCII

    ♦ Na-akwado okpomọkụ ọrụ nke -40 ~ 85°C

    ♦ Na-akwado mpaghara data: 2 serial Modbus-RTU/ASCII ruo PROFIBUS ọnụ ụzọ na Max.ntinye 1440 bytes na Max.mmepụta 1440 bytes

    ♦ Na-akwado otu nrụpụta igodo

    ♦ ODOT-PNM02 V2.0 na-akwado oghere kacha: 50

    ♦ ODOT-PNM02 V2.1 na-akwado ndị ohu 60 (200 na-agụ ma dee iwu)

  • ODOT-S4E2: 4 Oghere Usoro Modbus RTU/ASCII ka Modbus TCP ntụgharị

    ODOT-S4E2: 4 Oghere Usoro Modbus RTU/ASCII ka Modbus TCP ntụgharị

    ♦ Na-akwado ntụgharị protocol n'etiti Modbus-RTU na Modbus-TCP

    ♦ Na-akwado njikọ nke ndị ahịa TCP5 n'otu oge

    ♦ ODOT-S2E2 na-akwado 2*RS485

    ♦ ODOT-S4E2 na-akwado wiring nke RS485/RS232/RS422

    ♦ Ọdụ ụgbọ mmiri ọ bụla na-akwado Modbus masterand ohu

    ODOT-S2E2: 2 Oghere Usoro Modbus-RTU/ASCII ruo Modbus-TCP Server ọnụ ụzọ ámá

    ODOT-S4E2: 4 Oghere Usoro Modbus-RTU/ASCII ruo Modbus-TCP Server ọnụ ụzọ ámá

    ♦ Na-akwado otu nrụpụta igodo

    ♦ Ọnụ ụzọ ámá na-arụ ọrụ mode: nnyefe transperent, adreesị nkewa

  • ODOT-S2E2: 2 Oghere Usoro Modbus RTU/ASCII ka Modbus TCP Ntụgharị

    ODOT-S2E2: 2 Oghere Usoro Modbus RTU/ASCII ka Modbus TCP Ntụgharị

    ♦ Na-akwado ntụgharị protocol n'etiti Modbus-RTU na Modbus-TCP

    ♦ Na-akwado njikọ nke ndị ahịa TCP5 n'otu oge

    ♦ ODOT-S2E2 na-akwado 2*RS485

    ♦ ODOT-S4E2 na-akwado wiring nke RS485/RS232/RS422

    ♦ Ọdụ ụgbọ mmiri ọ bụla na-akwado Modbus masterand ohu

    ODOT-S2E2: 2 Oghere Usoro Modbus-RTU/ASCII ruo Modbus-TCP Server ọnụ ụzọ ámá

    ODOT-S4E2: 4 Oghere Usoro Modbus-RTU/ASCII ruo Modbus-TCP Server ọnụ ụzọ ámá

    ♦ Na-akwado otu nrụpụta igodo

    ♦ Ọnụ ụzọ ámá na-arụ ọrụ mode: nnyefe transperent, adreesị nkewa

  • ODOT-DPM01: Modbus-RTU ka ọ bụrụ Profibus-DP Ntụgharị

    ODOT-DPM01: Modbus-RTU ka ọ bụrụ Profibus-DP Ntụgharị

    ♦ Na-akwado ntụgharị protocol n'etiti Modbus na PROFIBUS

    ♦ Na-akwado RS485, RS422 na Rs232

    ♦ Na-akwado Modbus nna ukwu na ohu, ma na-akwado RTU ma ọ bụ ASCII

    ♦ Na-akwado gburugburu ọrụ nke -40 ~ 85 ° C

    ♦ PROFIBUS-DP: Max.Ntinye 244 bytes, Max.Mpụta 244 bytes

    ♦ DPM01: 1-ụzọ Modbus gaa n'ọnụ ụzọ ohu PROFIBUS, nchikota ntinye na mmepụta bụ 288 bytes.

    ♦ DPM02: (nhazi) 1-ụzọ Modbus-RTU gaa PROFIBUS ọnụ ụzọ ohu, nchikota ntinye na mmepụta bụ 488 bytes.

  • MG-CANEX nwere ike imepe na Modbus TCP ntụgharị

    MG-CANEX nwere ike imepe na Modbus TCP ntụgharị

    Ihe Ntụgharị Protocol MG-CANEX

    Cano imepe ka Modbus TCP ntụgharị protocol

    MG-CANEX bụ ihe ntụgharị protocol sitere na CANopen gaa Modbus TCP.Ngwa ahụ na-arụ ọrụ dị ka onye nwe ya na netwọk CANopen na ọ nwere ike jikọọ na ọkọlọtọ CANopen ngwaọrụ ohu.Nbufe data na-akwado PDO, SDO, na njikwa njehie na-akwado Heartbeat.Ọ na-akwado izipu ozi gakọrịta na nke asynchronous.

    Dị ka ihe nkesa TCP na netwọk Modbus TCP, ndị ahịa TCP 5 nwere ike ịnweta ngwaọrụ ahụ n'otu oge, yana enwere ike jikọọ ya na njikwa PLC na ụdị nhazi nhazi dị iche iche.Ọ nwekwara ike jikọọ transceiver anya na iji ghọta nnyefe data dị anya.

  • ODOT-S1E1 V2.0: Ụzọ Oghere Usoro

    ODOT-S1E1 V2.0: Ụzọ Oghere Usoro

    Nke a bụ ihe ntụgharị mepụtara site na Sichuan Odot Automation System Co., LTD n'etiti RS232/485/422 na TCP/UDP.This protocol Ntụgharị nwere ike jikọọ Oghere Usoro n'ọdụ ụgbọ mmiri ngwaọrụ na Ethernet na-aghọta netwọk nkwalite nke Oghere Usoro ọdụ ụgbọ mmiri ngwaọrụ.

    Ihe ntụgharị protocol na-akwado ọrụ nke "nfefe data", nke enwere ike ịtọ dịka onye ahịa ma ọ bụ ihe nkesa.Ọrụ a nwere ike ịghọta nzikọrịta data n'etiti PLC, ihe nkesa na ngwaọrụ Ethernet ndị ọzọ yana ngwaọrụ ọdụ ụgbọ mmiri dị n'okpuru.

    Na-akwado ihe nkesa TCP na TCP ahịa nnyefe transperent
    Na-akwado nnyefe uzo UDP na ọdụ ụgbọ mmiri serial mebere
    Na-akwado nnyefe uzo na ma ọ bụ na-enweghị protocol.Nbufe uzo protocol na-akwado MODBUS RTU/ASCII
    Na-akwado paramita nhazi ihe nchọgharị WEB (Paịlụ nkịtị) Ọnụ ọgụgụ baud ọdụ ụgbọ mmiri Serial 1200 ruo 115200 bps

  • ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface na EtherNet

    ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Interface na EtherNet

    ♦ arụnyere na PPI/MPI/PROFIBUS ọdụ ụgbọ mmiri PLC, n'ozuzu na-enweghị mpụga ike ọkọnọ.

    ♦ Kwado ndị ọkwọ ụgbọ ala nkwukọrịta Siemens S7 Ethernet, gụnyere MicroWIN, STEP7, TIA Portal, WinCC wdg.

    ♦ Ejikọtara ya na ihe nkesa Modbus-TCP, enwere ike ịmegharị mpaghara data Modbus na-akpaghị aka ma ọ bụ dezie ya na map iji debanye aha S7-200/300/400

    ♦ S7TCP njikọ na Modbus-TCP nkwurịta okwu nwere ike na-aghọta n'out oge

    ♦ Ruo 32 njikọ kọmputa na-akwado

    ♦ MPI ka S7 Ethernet/Modbus-TCP ntụgharị

    ♦ Na-akwado nrụpụta otu igodo